Low Cost Journal,International Peer Reviewed and Refereed Journals,Fast Paper Publication approved journal IJEDR(ISSN 2321-9939) apply for ugc care approved journal, UGC Approved Journal, ugc approved journal, ugc approved list of journal, ugc care journal, care journal, UGC-CARE list, New UGC-CARE Reference List, UGC CARE Journals, ugc care list of journal, ugc care list 2020, ugc care approved journal, ugc care list 2020, new ugc approved journal in 2020, Low cost research journal, Online international research journal, Peer-reviewed, and Refereed Journals, scholarly journals, impact factor 7.37 (Calculate by google scholar and Semantic Scholar | AI-Powered Research Tool)
INTERNATIONAL JOURNAL OF ENGINEERING DEVELOPMENT AND RESEARCH
(International Peer Reviewed,Refereed, Indexed, Citation Open Access Journal)
ISSN: 2321-9939 | ESTD Year: 2013

Current Issue

Call For Papers
June 2023

Volume 11 | Issue 2
Last Date : 29 June 2023
Review Results: Within 12-20 Days

For Authors

Archives

Indexing Partner

Research Area

LICENSE

Paper Details
Paper Title
A CT Saturation Detection Algorithm Using Secondary Current Third Difference Function
Authors
  Rajnish Prasad Pandey,  Dr. R. N. Patel

Abstract
This paper proposes an algorithm for detecting current transformer (CT) saturation by analyzing a secondary current. The current has point of inflection where saturation begins and ends. Then, discontinuity in the first difference of the current arises at the next instants of points of inflection, where the second and third differences of the current may have large values enough to detect saturation. In this paper third difference is used because it is more effective than second difference in terms of saturation detection. Ideally the function of current transformer is to transform and reproduce the primary current in the secondary circuit in a most faithful manner. Practically, some distortion in ratio and phase angle can be tolerated. How much of these distortions can be tolerated depend upon the application for which the CT is being used. These allowable errors are specified in different standards. Under normal operating conditions CT reproduces the primary current in the secondary side with good degree of accuracy, however, during abnormal operating conditions CT is likely to get saturated. A current transformer (CT) can saturate, for various reasons, like: attempting to transform heavy primary fault currents, heavy burden on the secondary side of current transformer or transient DC offset in the primary fault current. The method for CT saturation detection that has been simulated is, An algorithm for detecting CT saturation using second current third difference function.

Keywords- Current Transformer Saturation, difference, point of inflection, remanent flux
Publication Details
Unique Identification Number - IJEDR1402236
Page Number(s) - 2774-2779
Pubished in - Volume 2 | Issue 2 | June 2014
DOI (Digital Object Identifier) -   
Publisher - IJEDR (ISSN - 2321-9939)
Cite this Article
  Rajnish Prasad Pandey,  Dr. R. N. Patel,   "A CT Saturation Detection Algorithm Using Secondary Current Third Difference Function", International Journal of Engineering Development and Research (IJEDR), ISSN:2321-9939, Volume.2, Issue 2, pp.2774-2779, June 2014, Available at :http://www.ijedr.org/papers/IJEDR1402236.pdf
Share This Article


Article Preview

ISSN Details




DOI Details



Providing A digital object identifier by DOI
How to get DOI?

For Reviewer /Referral (RMS)

Important Links

NEWS & Conference

Digital Library

Our Social Link

© Copyright 2024 IJEDR.ORG All rights reserved